   Cintec™ Fire Resistant Anchors   

In view of the recent fires and loss of life in refurbished buildings, Cintec™ has been fully aware of the danger of fire and has always produced remedial fire resistant anchors and reinforcement.

In the past few years, fire has been an increasing concern when buildings are being retrofitted, restored, or modernized, increasing the need for fire resistant anchors. On June 14th, 2017, a fire broke out in the 24 storey Grenfell Tower, widely reported as the worst residential fire to take place in the U.K since the second World War, due to failures by design and lack of fire resistant anchors.

As concerns over fire safety and fire resistant anchors spread through the country, Prime Minister Theresa May ordered a public inquiry. As stated in the final report of the review of building regulations and fire safety, England is by no means alone in needing to improve building safety, as building regulations and fire resistant anchors are a global concern.

Under the terms of the EC Construction Products Directive, resistance to fire using fire resistant anchors is one of the essential requirements for which performance tests are required. In Europe, thin-joint mortars have become popular, thus there are a number of situations where fixings are made using organic polymers as either the tie body, or in the form of resin glues.  Such ties are not inherently fire resistant such as fire resistant anchors, and could fail and shorten the life of a cavity wall in a fire, or lead to the collapse of cladding resulting in danger to escaping occupants and fire fighters.

As a leader in structural preservation, Cintec™ has always been an advocate for the restoration of safe buildings through fire resistant anchors, as long ago as 1993 fire tests  were carried out by the internationally recognized Building Research Establishment in accordance with BS476(1) , ISO(2) , and CEN(3). The fire rig was designed for use in the measurement of the performance of Cintec’s™ fire resistant anchors in a fire situation while subjected to a mechanical load which might be a result of wind suction of fire-induced thermal movement.

Cintec’s™ remedial fire resistant anchors survived a two-hour test without failure of any of the samples. Every sample reached several hundred degrees in the part of the anchor nearest to the fire face. This indicates the fire resistant anchor system can be recommended for repair work to buildings requiring a fire rating of up to two hours.

.                                                                                                             

Cintec’s™ fire resistant anchors were later, unintentionally put to the test at the Fullers Brewery in London. The Cintec™ fire resistant anchors had been used extensively to repair and restore the Brewery’s facade. A fierce fire followed, destroying large sections of the building. Despite the brickwork being subjected to extremely high temperatures, tests revealed that the cementitious Cintec™ fire resistant anchors did not fail, performing to their original design. They retained their integrity and could be reused for the repair work.   If the fire resistant anchors were an epoxy or resin type, they would have melted, releasing potentially dangerous fumes in the process and have been easily pulled out, allowing the wall to collapse. One could say that the Cintec™ Anchors having survived the fire are in fact fire proof.

.                                                                                                                                   

In New York City, according to the NYC Buildings Department, adhesive anchors are not permitted to support fire-resistance rated construction unless the use of such anchors meets the conditions set forth in the acceptance criteria. Post-installed anchors in masonry must be designed in accordance with the NYC Construction Codes, describing the masonry substrate type and condition, as well as proof of pull tests.

Howard Zimmerman, the well-known NY Architects, had concerns about the lack of fire ratings for resin-based anchor systems in high rise apartments near Central Park, New York. After reviewing Fire Test Data and performance tests on a severely damaged building after a fire, it was determined that the Cintec™ fire resistant anchor was the best anchor to meet the project engineers’ concerns.

Cintec’s™ fire resistant anchors are the cementitious fire-resistant alternative to resin anchors. Since Cintec’s™ fire resistant anchors are based on reliable restoration materials, cementitious grout and stainless steel, they easily provided the elusive fire rating typically absent in other systems.


Fire Resistant Anchors Literature

Fullers Brewery Case Study

Strengthening Repair and Stabilization of High-Rise Buildings Brochure

BRE Fire Test


[1]  BS476: Part 20: 1987, Fire tests on building materials & structures. British Standards Institute, London, 1987

[2] ISO/DIS 834 – Fire resistance tests – Elements of building construction. Part 1: General requirements for fire resistance testing; Part 2: Fire resistance testing of non-loadbearing elements; Part : Fire resistance testing of loadbearing elements

[3] CEN prENYYY1, prENYYY2, prENYYY3 (Renumbered equivalents of ISO drafts).